Test Report July 2004 Safe Cell Tab

Shielding Effectiveness Test Report

 
   

Test Conclusion:  The Safe Cell Tab Possesses Shielding Effectiveness

in the Test Frequency Range 0.8 GHz - 10.525 GHz


 
   

 

Test Report No. 840370320 of July 2004


Shielding Effectiveness Test


   
SHIELDING EFFECTIVENESS (dB) AT FREQUENCY (GHz)
S A M P L E
0.800

1.900

10.525


SEpw

SEm

SEpw

SEm

SEpw

SEm

SAFECELLTAB,
D=2.699 g/cm3

47.3

44.1

47.7

44.7

46.9

45.4













Signal Absorption,
percent
 
99.998

99.996

99.998

99.997

99.998

99.997

TEST DESCRIPTION

1 - The test per ASTM D4935, IEEE-STD-299-1991, FED-STD-1037, MIL-STD-188-125A, MIL-STD-461C and MIL-STD-462. Test conditions: T=22°C, RH=39%, P=101.4 kPa.

2 - Each magnitude of the plane-wave (SEpw) and magnetic (SEm) shielding effectiveness in the table above is an average from six (6) test runs at each of the three test frequencies on each of the six samples tested. The experimental error evaluated by the partial derivatives and least squares methods does not exceed 6%. The data on the standard deviation are kept on file at CIEMS.

3 - The linear arrangement of the generator and receiver antennas and the test specimens meets the requirements of MIL-STD-188-125A and the EM Performance Test Plan CIEMS-3RFRT-393001.

4 - Instruments and devices used
   - Signal Generator Model 8592B HP (50 MHz to 22 GHz)
   - Analyzer Model 8593E HP (9 kHz to 22 GHz)
   - Gunn Diode Microwave Transmitter Model WA-9314B PSC
   - Dual Preamplifier Model 8847F HP
   - Oscilloscope Model IO-4540 HK with Amplifier Model 8347A HP
   - Antennas: HP11968C, HP11966E, HP11966F and Dipole Antenna Set HP11966H
   - Magnetic Field Pickup Coil HP11966K, Active Loop H-Field HP11966A
   - Goniometer Model 3501-08 F-DM, Starrett Dial Indicator Model 25-109 (1.25 um/div)
   - Digital Hygrothermometer Model 63-844 MI, Barometer Model 602650 SB.

5 - The equipment meets the applicable NIST, ASTM, ASME, OSHA and State requirements and was calibrated with the standards traceable to the NIST. The calibration was performed per ANSI/ASO/ASQ-Q9004-2000, ISO 10011-1:1992, ISO 10012-2:1997, MIL-STD-45662, MIL-I-45208, NAVAIR-17-35-MTL-1. CSP-1/03-93 and the instrument manufacturers' specifications.

6 - The equipment passed a periodic accuracy test in June 2004. The linear measure instruments will be calibrated in December 2004. Next test - June 2005.

TEST ENGINEER: 29

DIVISION MANAGER: Cynthia Smythe

CIEMS
2115 Flame Tree Way - Hemet, CA 92545-7803
(951) 929-2659 - Fax (951) 929-1057

Safe Cell Tab, Inc. P.O. No. 062204 of June 29, 2004

Division of Electric Measurements and Devices